Co-op and condo access control · NYC

Access control built for NYC co-ops and condos.

Who gets into the lobby, who can ride the elevator to which floors, and who can use the laundry, package room and roof. We install key fob and card access, intercom integration and elevator controls, and prepare the proposal your board reviews.

Licensed and insuredOn-site or cloud, your choiceBoard-ready proposals1-year warranty on work and parts
Plan CC-01 · Building section · Who reaches what
FOB · RESIDENT 7AANY TIME · LAUNDRY 7 TO 22 FOB · PORTER · STAFF06:00 TO 15:00 · SERVICE CAR CODE · CONTRACTOR FOR 7BWEEKDAYS 8 TO 5 · ENDS APR 25 7B · RENOVATION 7A7B6A6B5A5B4A4B3A3B2A2B R765432L ROOFROOF DECK LOBBYPACKAGESOFFICE LAUNDRYSTORAGESUPERSERVICE PASSENGERSERVICE CAR
Resident 7A. The fob opens the front door, package room, laundry and roof. The passenger car stops only at the lobby, basement and 7. OpensLockedElevator stop

Residents, staff and contractors each get their own credential and hours. Nobody needs a physical key that circulates around the building.

What co-ops and condos need 06

Every access point in the building, under control.

The board has a say, every unit has shareholders or owners, and the amenity spaces have to be managed without changing locks every time someone moves.

CC-01.1Lobby

Lobby entry system

Front door access by key fob, card or PIN. A visitor intercom with unit ring-through, delivery access codes, and an audit log of every entry, which helps when the board has questions about building activity.

CC-01.2Elevator

Elevator access control

Elevator buttons restricted by floor. Residents reach only their floor and the shared floors, and visitors cannot reach residential floors unescorted, a common requirement in NYC co-ops with shared elevator cabs.

CC-01.3Amenities

Package room and amenity access

Key fob access to the package room, mail room, laundry room and amenities. Set hours for the laundry and roof from the management software, with no lock changes.

CC-01.4Per unit

Per-unit fob management

Each unit gets a set number of fobs programmed to its access level. A lost fob is turned off in the management software and stops working immediately: no locksmith, no rekeying. The replacement is programmed and handed over.

CC-01.5Board

Board and management coordination

We prepare a written proposal with hardware specs and installation diagrams, laid out for board review, with the answers boards usually ask for before they approve a job.

CC-01.6Visitors

Visitor and contractor access

Temporary codes for contractors, housekeepers and pet walkers, limited by time and ending on their own. No physical keys circulating around the building indefinitely.

Scalable, phase by phase

Approve the lobby now. Add the elevator later.

Step through how a co-op system grows, and what the board sees in the packet for each phase.

CC-02 · Board packet · Built in phases
ROOFFLOORS2 TO 7LOBBYBASEMENT PANEL FRONT DOOR INTERCOM EXISTING WIRE, REUSED DELIVERY CODE PHASE 1 CAB READER RELAYMODULE FLOORS PHASE 2 ROOF DOOR GYM LAUNDRY PACKAGE ROOM PHASE 3 SAME PANEL AND RISER IN EVERY PHASE
Phase 1 · Lobby FRONT DOOR
AddsFront door reader and strike, video intercom with unit ring-through, delivery access codes, and an audit log of every entry.
WiringExisting intercom wiring in conduit is tested and reused where it is sound. Older two-wire runs may need new cable, and we say so up front.
ResidentsA set number of fobs per unit, each programmed to that unit's access level.
In the packetAccess point diagram, hardware specs, scope of work, and what each door does in a power outage.

Start with the lobby and add the elevator or amenities later. The system grows on the same panel, without replacing hardware or rewiring doors that are already done.

Technology 06

The hardware and software behind the system.

Commercial-grade access control built for a co-op or condo, from the reader at each door to the management portal your property manager uses every day.

ItemEquipment schedule · Co-ops and condos
E-01

Key fob and card readers

One fob · every door

Proximity readers at each controlled door. Residents carry one fob that works at every access point in the building: lobby, elevator, laundry and amenity spaces.

E-02

Access management, on-site or cloud

Your choice

Management adds and removes credentials from a web portal in any browser, turns off lost fobs immediately and pulls access logs without calling anyone. It can run on a cloud platform for remote management, or on a local server with no monthly software fee.

E-03

Intercom integration

Video or audio

A video or audio intercom at the building entry. Residents answer on their phone or the in-unit panel. It works with most intercom systems already wired into the building.

E-04

Electric strikes and magnetic locks

Fail-safe · fail-secure

Commercial-grade door hardware built for constant use in busy lobbies. We pick the lock for each door around its use and the building's fire and life safety requirements. A magnetic lock needs a free way out from inside at all times.

E-05

Audit trail and reporting

Time · credential · door

Every access event is logged with the time and credential ID. Management can pull a report for any period, for incident investigations or board questions about after-hours activity.

E-06

Scalable credential system

Lobby first

Start with lobby access and add elevator control or amenity access later. The system grows with the building without replacing hardware or rewiring doors.

How it works 04

From board approval to move-in ready.

Co-op and condo jobs have more steps than a standard commercial install. We plan for the places delays usually come from.

01

Building walkthrough

We assess every controlled access point: lobby, elevator, laundry, package room and amenity spaces. Existing hardware and wiring are documented, and we work out what can be reused before any proposal is written.

02

Proposal for board approval

A written proposal with access point diagrams, hardware specs and scope of work, laid out for co-op board or condo association review. What boards usually ask for is included up front.

03

Installation

Door hardware, card readers, the controller and software setup. We work around the people living there and keep disruption low, and no door is left out of service overnight.

04

Management setup and handoff

Your property manager is trained on the portal: adding and removing credentials, pulling access logs and creating temporary codes. Full documentation is included, so day-to-day operation does not depend on us.

Frequent questions 05

Co-op and condo access control, answered.

Do we need board approval to install an access control system in common areas?

Yes, in most NYC co-ops and condos. The lobby, elevator and amenity spaces are shared property, so changes need board or managing agent approval. We provide a complete proposal package with hardware specs and installation plans that you can submit directly to your board or managing agent. It includes what boards typically ask for, so you are not going back and forth for months.

Can we keep existing intercom wiring and just upgrade the hardware?

Often, yes. If your building has intercom wiring in conduit, we can frequently reuse it for the new system, which keeps cost down and avoids opening finished walls. We test the existing wiring during the walkthrough and tell you exactly what is reusable before you commit. Buildings from after the 1980s with structured cabling usually reuse a lot. Older buildings with two-wire systems sometimes need new runs, and we tell you that up front.

How do residents get replacement fobs if they lose one?

The property manager turns off the lost fob in the web portal: no locksmith, no rekeying, no waiting for anyone to come on site. It stops working at every door the moment it is turned off. A new fob is programmed for the same access level and handed to the resident. You also get an audit trail showing when the lost fob was last used and which doors it opened, which helps if there is any question about unauthorized entry.

Can we restrict elevator access so visitors cannot reach residential floors?

Yes. Floor buttons require a valid credential before the elevator will go to that floor. Visitors arriving in the lobby can reach the lobby and any designated common floors, but not residential floors without a resident. Each resident's credential is programmed for their own floor and the shared floors they are allowed. This is a standard installation in NYC co-ops and works with most existing elevators. We confirm compatibility during the walkthrough.

What happens to access during a power outage?

Every controlled door is set to fail-safe or fail-secure based on its function. Fail-safe doors unlock when power is lost, which egress paths need. Fail-secure doors stay locked, which is standard for lobby entry doors, with a mechanical key override for emergencies. We pick the lock for each door around its use and the building's fire and life safety requirements. Battery backup on the access panel keeps the system running through brief outages. The fail mode for every door is set during design, so the board knows what happens in an outage before anything is installed.

Residential property types 05

Access control for every home and building.

Single-family homesView → Apartment buildingsView →
Co-ops and condosThis page
TownhousesView → Rental propertiesView →
Get started

Ready to upgrade your building's access control?

We walk your building, prepare a board-ready proposal, and install a system your property manager can actually use. Every door controlled, every entry logged.

Most people start here Get a Free Quote Tell us the number of units, entrances, elevators and amenity rooms. Talk it through Call 212-347-5400 Speak with someone who does the installs. Send a photo Text 646-838-2300 A photo of the lobby door or the intercom panel speeds up the quote.