Damaged network cable? Repair starts at the fault, not a blind re-pull.
A contractor cut through a run, a plumber ran a pipe through a riser, or rodents chewed a cable in the ceiling. We locate the exact break, splice or re-pull that section, and test it to spec.
A contractor, electrician or renovation crew cut a cable while working on something else. A clean break at a known point. We splice or re-pull that section.
Cut during construction
A contractor, electrician or renovation crew cut a cable while working on something else. A clean break at a known point. We splice or re-pull that section.
Crushed inside a wall
A shelf anchor, a picture hanger or debris crushed the cable without cutting it. Hard to see, easy to find with a cable tester. We locate the pinch point.
Rodent damage in the ceiling
Chewed insulation, exposed wires, or a cable chewed through. Common in drop ceilings and crawl spaces. We splice at the damage and check the cables next to it.
Riser hit by plumbing work
A plumber ran a pipe through the riser chase and nicked or crushed the cables sharing it. Common after a repipe. We trace and repair at the damage.
Water damage
A roof leak, condensate or a window leak soaked a bundle. Some runs die right away, others fail months later. We find which runs are affected and repair or re-pull them.
Fire or heat damage
An electrical fire, lightning or heat damaged the insulation and conductors. We replace the section with code-compliant cable, plenum where required.
The five common scenarios, most common first.
Low-voltage runs are rarely on anyone else's drawings, so other trades hit them.
Construction and renovation
Trades working in walls, ceilings or chases damage cables they did not know were there. The runs are not on the contractor's plans, and the damage hides behind the drywall. We find the break after the work.
Hangers, anchors and shelves
Picture hangers, shelf brackets and TV mount anchors drilled through cables in the wall. Common in tenant buildouts. Found with a cable tester.
Plumbing and HVAC work
Chases shared between pipes and cables. Repipe work nicks cable, duct work crushes it, condensate corrodes it. Common in mid-rise and pre-war buildings.
Rodents
Rodents chew insulation in drop ceilings, crawl spaces and attics. The damage is usually at one or two points. We splice and screen the access path where we can.
Water
Roof leaks, broken pipes, window leaks and condensate. Water-damaged copper can test fine the day it is wet and fail months later as it corrodes.
Cable cut during construction?
Do not let anyone patch it with tape or a coupler. We find the break, splice or re-pull that section, and certify it to spec, with photos and test reports if the damage goes on a contractor's bill or an insurance claim.
You do not need the original installer.
We trace damage in modern Cat6A installs and in 30-year-old Cat3 phone runs alike. The tools and the skills work across generations.
The cable types we work with
Tested repair across copper and fiber, plus coax, speaker cable and specialty low-voltage.
The documentation after the fix
A splice without a test report is a guess. Every repair gets a Fluke DSX test on copper or an OTDR trace on fiber, with a PDF for your records, insurance or property manager.
We splice when it meets spec. Re-pull when it does not.
When we splice
Modern splices, crimp-style for copper and fusion for fiber, can meet Cat6, Cat6A, OM3 and OS2 spec, and we certify them with Fluke tests. For damage at one point, a splice is faster and cheaper than re-pulling the run.
When we re-pull
Several damage points on the same run, cable exposed to water or chemicals, runs that must meet a spec where splices are not accepted, or runs that were failing tests before the damage. We tell you honestly which applies.
Explore cabling installation →How a damaged-cable call goes.
Four steps, and every repair is tested before we leave.
Phone triage
Which runs, what caused it if known, access and timeline. Five minutes tells us what tools and splice gear to bring.
Trace and locate
We tone the runs and find the damage. Where it is visible we look. Behind drywall, a cable tester gives the distance to the fault. The first 20 minutes finds it.
Splice or re-pull
Most copper splices and short re-pulls are same-visit. Fiber fusion splices get an OTDR check. Long re-pulls are scheduled with a firm return date.
Certify and document
Every repair tested to spec, PDF emailed to you, labels updated. Documentation for insurance or property management included.
Damaged cable FAQ.
Cable damaged? Pick the fastest way to reach us.
Talk to a technician and get an honest arrival window.
SEND A PHOTOText 646-838-2300A photo of the damage or the area that was worked on speeds up the fix.
NOT URGENTRequest a quoteDescribe the system and we will come back with a clear plan.