Dead network jack? We trace it, fix it and test it.
One jack at the wall stopped working, a drop from an old office layout is dead, or a port that worked yesterday is dark today. We trace the run end to end, find the fault, re-terminate or splice, and hand you the Fluke test report.
No link light, no address, nothing. The run between the patch panel and the wall plate broke, or a termination at either end failed. A clean fix once located.
Completely dead
No link light, no address, nothing. The run between the patch panel and the wall plate broke, or a termination at either end failed. A clean fix once located.
Link light, no data
The device shows a link light but cannot talk on the network. One pair is bad, a termination only partly made contact, or the switch port is set wrong. Testable in minutes.
Stuck at 100M, not gigabit
The classic sign that only 2 of the 4 pairs are terminated right. The device drops to 100M, which needs only 2 pairs. Re-terminate and gigabit comes back.
Several jacks dead in one area
A group of jacks or a whole conference room went dark together. A shared cable path was damaged, or the switch ports for that side failed. We check both.
Dead after construction
It worked before a buildout, a facade job or a renovation. A cable was cut, pulled or damaged during the work. We trace to the fault and repair that section.
Unlabeled, unknown jack
A jack that may or may not be live, and no documentation. We tone it to the patch panel, test it and label both ends. You leave with a known-good drop.
The five common culprits, in the order we check them.
Most dead jacks are a termination at one end. We check the ends before we touch the run.
Bad termination at the wall
The keystone came loose, a wire slipped out of its slot, or the punch-down was never clean. The most common cause by far. Re-terminate with the right tool.
Bad termination at the patch panel
A wire pulled out at the panel, or got disturbed during work on the port next to it. Checked at the panel in minutes, fixed with a clean re-termination.
Patch cord or switch port
The jack and the run are fine. The patch cord to the switch failed, or the switch port died. The fastest fix of all once we check it.
Damage in the middle of the run
A shelf anchor, a plumber, a ceiling crew or rodents hit the cable. We tone the run to find the fault, then splice or re-pull that section.
Water and corrosion
Older runs in buildings with roof or window leaks corrode at splices or in a damp patch panel. Common in pre-war buildings. We repair at the fault.
Several jacks dead at once?
When a group of jacks or a conference room goes dark together, it is rarely the jacks. A shared cable path was damaged, or the switch ports for that side failed. We check both before we touch a wall plate.
You do not need the original installer.
Cabling is not about brands. It is about tracing and repairing correctly. We work on every cable plant in the field, from pre-war Cat3 to modern Cat6A.
The cable types we work with
Tested cable work across copper and fiber, plus coax, speaker cable and the mix of specialty low-voltage you find in a mature building.
The testing and documentation side
Blind cable work is a waste of money. We tone every run, test every termination, and hand you the Fluke test PDF so you know what you are getting.
Terminations first. Re-pull only when necessary.
When we re-terminate
Most dead-jack calls are a bad termination at one end or the other. A clean re-termination with the right tool and the jack is back. We do not re-pull cable when the run is still good.
When we re-pull
The cable is damaged mid-run beyond a splice, it was exposed to water or chemicals, or it cannot carry the speed you need, such as Cat5e asked to do 10G. Then we lay out the pull with honest timelines.
Explore cabling installation →How a dead-jack call goes.
Four steps, and every repaired run is tested before we leave.
Phone triage
Where the jack is, what used to work, what is plugged in, any recent construction or office changes. Five minutes tells us what tools to bring.
Tone and test
We tone the cable at the jack and trace it to the patch panel. If both ends and the run test clean, we check the switch port and patch cord. The fault is usually clear within 15 minutes.
Re-terminate, splice or re-pull
Most repairs are a re-termination at one end. Mid-run damage gets a tested splice or a re-pull of that section. Same-visit except long or difficult re-pulls.
Certify and label
Every repaired run gets a Fluke DSX test, and the PDF goes to you. Jack labels updated, patch panel ports documented.